##plugins.themes.huaf_theme.article.main##

Abstract

The majority of cruise ship wastewater comes from toilets and has a low COD/N ratio, making it difficult to remove TN. QCVN 100:2018/BGTVT applies stricter requirements, especially for TN standards. Examining the application of an A/O model in aerobic tanks to treat cruise ship wastewater under different DO conditions. The results showed that TN treatment efficiency for DO conditions 3 – 3.5 mg/l, 2 – 2.5 mg/L, and 1 – 1.5 mg/L was equal to 37.66%, 52.51%, and 70.24%, respectively. According to research, in order to remove TN to meet QCVN 100:2018/BGTVT, DO in aerobic tanks should be controlled at concentrations of 1 - 1.5 mg/L, and Carbon should be added to increase treatment efficiency and stabilize output water quality.        


Keywords: Cruise ship wastewater, A/O, TN removal, dissolved oxygen.

##plugins.themes.huaf_theme.article.details##

Section
Articles
Author Biographies

Truong Trong Danh*

Viện Công nghệ sinh học và môi trường, Trường Đại học Nha Trang

Hoang Ngoc Anh

Viện Công nghệ sinh học và môi trường, Trường Đại học Nha Trang

Nguyen Thi Ngoc Thanh

Viện Công nghệ sinh học và môi trường, Trường Đại học Nha Trang

Le Phuong Chung

Viện Công nghệ sinh học và môi trường, Trường Đại học Nha Trang